An Arizona contractor license has two parts that matter to you: the type (residential, commercial or dual) and the class, a code like B-3, R-37 or CR-42 that sets what work the contractor is allowed to do. A licensed contractor working outside its class is "knowingly contracting beyond the scope" of the license, which is grounds for discipline (A.R.S. 32-1154(A)(16)). This page explains the codes you will see on the ROC Contractor Search and which ones fit common home jobs.

Residential, commercial and dual

A.R.S. 32-1102 divides the contracting business into seven types:

  • General commercial building, general engineering, and specialty commercial contracting
  • General residential and specialty residential contracting
  • General dual and specialty dual contracting

Residential work is anything within residential property lines on houses, townhouses, condominiums or cooperative units and their appurtenances (A.R.S. 32-1101(A)(10)). The ROC says commercial contracting "is anything other than residential" (ROC: License Classifications).

For your house, the license must be residential or dual. That also matters for money: only a residential license holder's customers can claim from the Residential Contractors' Recovery Fund, and the contractor must have held a valid residential license when you signed, paid or work started (A.R.S. 32-1132). A dual license counts, because dual licensees fund the Recovery Fund too (32-1152(C)).

How to read the codes

Prefix Meaning Examples
A Commercial engineering A General Engineering, A-9 Swimming Pools
B-1, B-2 Commercial general building B-1 General Commercial, B-2 General Small Commercial
C Commercial specialty C-11 Electrical, C-37 Plumbing
B (no number), B-3, B-4, B-5, B-6, B-10 Residential general B General Residential, B-5 Swimming Pool
R Residential specialty R-11 Electrical, R-42 Roofing
KA, KB Dual general KB-1 Dual Building, KB-2 Dual Residential and Small Commercial
CR Dual specialty CR-37 Plumbing, CR-39 Air Conditioning

An "R" after the number, such as R-37R or R-39R, means the scope is restricted to what the license title says (A.A.C. R4-9-103(B)). An R-37R Gas Piping contractor can run gas lines but cannot replumb your house.

General residential classes

These scopes come from A.A.C. R4-9-103:

  • B General Residential Contractor. May construct and repair all or any part of a residential structure or appurtenance. Electrical, plumbing, air conditioning, boilers, swimming pools, spas and water wells must be subcontracted to appropriately licensed contractors.
  • B-3 General Remodeling and Repair Contractor. May remodel and repair an existing residential structure or appurtenance, with the same subcontracting rule for electrical, plumbing, mechanical, boilers, pools, spas and water wells. The R-7 carpentry scope is included.
  • B-5 and B-6 General Swimming Pool Contractor (B-6 includes solar). Pool builders. Pool contracts carry extra rules, such as a down payment cap of 15% (A.R.S. 32-1158.01).
  • B-10 Pre-Manufactured Spas and Hot Tubs.

R-62 Minor Home Improvements

R-62 is the license for small jobs. For projects of $5,000 or less including labor and materials, it allows remodeling, repairs and improvements to existing structures. It does not allow structural work, including load-bearing masonry or concrete (on-grade flatwork excepted) and load-bearing carpentry (patio and porch covers excepted). Electrical, plumbing, air conditioning and boiler work must be subcontracted (R4-9-103). If an R-62 contractor bids $7,500 on your project, that bid is outside its license.

Dual general classes

From A.A.C. R4-9-104:

  • KB-1 Dual Building Contractor. Combines the B-1 General Commercial and B General Residential scopes.
  • KB-2 Dual Residential and Small Commercial. Combines the B-2 General Small Commercial and B General Residential scopes.
  • KA Dual Engineering, KA-5 and KA-6 Dual Swimming Pool (KA-6 includes solar).

For your home, a KB-1 or KB-2 contractor can do what a B contractor can do, including the requirement to subcontract trade work.

Specialty classes for common home jobs

Trade Residential Dual What the scope covers
Electrical R-11 CR-11 Install and repair residential electrical systems
Plumbing R-37 (includes solar and all R-37R subclasses) CR-37; CR-77 includes solar Water and gas piping, fire sprinklers, sewage treatment systems, fixtures and vents
Air conditioning R-39 (includes solar and all R-39R subclasses) CR-39; CR-79 includes solar Comfort AC, refrigeration, evaporative cooling, ventilating and heating
Evaporative coolers only R-39R Evaporative Cooling and Ventilators CR-58 Comfort Heating, Ventilating, Evaporative Cooling Restricted to that equipment
Roofing R-42 CR-42 Tile, shingles, shakes, slate, metal roofing, urethane foam, and the weatherproofing and flashing they need
Painting R-34 CR-34 Surface prep, paint, wallpaper, decorative texture, liquid floor and wall coatings
Concrete R-9 CR-9 Concrete, concrete products and accessories
Fencing R-14 CR-14 Metal, wood and block fencing, automatic gates; excludes retaining walls
Hardscape and irrigation R-21 CR-21 Non-loadbearing concrete, pavers, decks up to 29 inches, garden walls and fences up to 6 feet, retaining walls up to 3 feet, low-voltage landscape lighting
Glazing R-65 CR-65 Glass, window film, blinds and shutters, glass-holding frames
Drywall R-10 CR-10 Gypsum board and ceiling grid systems
Masonry R-31 CR-31 Brick, block, adobe, insulating concrete forms
Insulation R-40 CR-40 Insulation, including radiant barriers
Water treatment and misters R-54 CR-54 Water conditioning equipment, misting systems, exchange tanks

Sources: A.A.C. R4-9-103 and R4-9-104.

Arizona notes on these scopes

  • AC work and panels. The R-39 scope allows a new circuit on an existing service panel or sub-panel but excludes installing a new panel (R4-9-103). If your heat pump upgrade needs a panel upgrade, an R-11 or CR-11 electrician does that part.
  • Hard water and misters. R-54 Water Conditioning Equipment covers water conditioning equipment and patio misting systems, with the piping and low-voltage controls they need (R4-9-103).
  • Hardscape and xeriscape. R-21 is the class for pavers, low walls and drip irrigation. R-21 work involving fire pits or barbecues still needs the electrical, plumbing and gas done by a properly licensed contractor (R4-9-103). A gardener doing lawn, garden, shrub and tree maintenance needs no ROC license at all (A.R.S. 32-1121(A)(16)).
  • Retaining walls. A fence contractor's R-14 excludes them. An R-21 can build one up to three feet tall measured from the lower grade. A taller wall needs a contractor whose class covers it, and check your city's permit rules.
  • Solar. Installing a solar energy device also requires qualifying as a solar contractor under Title 32, Chapter 10, Article 4 (A.R.S. 32-1170.01).

Restricted licenses

The ROC can grant a restricted license (KE, KO, CR-5 or CR-29) confined to a specialized area of construction. The contractor must stay within the scope written on the license (A.A.C. R4-9-105). On the Contractor Search, read the full classification description, not just the code.

Exams

To qualify for a class, the qualifying party passes any required trade exam and Arizona's Statutes and Rules Exam (A.R.S. 32-1122(E)). The ROC accepts NASCLA exams for B-1, B-2, CR-11 and the C and R-11 electrical classes (ROC: License Classification Requirements). The ROC may waive a trade exam for a qualifying party who held the same classification within the past five years (ROC: Applying for a License).

Matching the license to your job

  1. Look up the contractor on the Contractor Search.
  2. Confirm the license is residential or dual and active.
  3. Read the class against the work in the bid. A remodel quote with new circuits and a relocated sink needs a B or B-3 general plus licensed R-11 and R-37 subcontractors, or a contractor holding those classes itself.
  4. Ask who the subcontractors are and check them too.

Related pages

Sources

Frequently Asked Questions

What is the difference between a B and a B-3 license in Arizona?

A B General Residential Contractor may build and repair all or any part of a residential structure. A B-3 General Remodeling and Repair Contractor may only remodel and repair an existing residential structure. Both must subcontract electrical, plumbing, air conditioning, boilers, pools, spas and water wells to properly licensed contractors (A.A.C. R4-9-103).

What can an R-62 contractor do in Arizona?

R-62 Minor Home Improvements covers remodeling, repairs and improvements to existing structures for projects of $5,000 or less including labor and materials. It excludes structural work, other than on-grade flatwork and patio or porch covers, and electrical, plumbing, air conditioning and boiler work must be subcontracted (A.A.C. R4-9-103).

What does CR mean on an Arizona contractor license?

CR classes are specialty dual licenses. Each one combines a commercial C class and a residential R class in one license, such as CR-11 Electrical, CR-37 Plumbing, CR-39 Air Conditioning, Refrigeration and Heating, and CR-42 Roofing (A.A.C. R4-9-104).

Which license does an evaporative cooler contractor need in Arizona?

Evaporative cooling falls within R-39 Air Conditioning and Refrigeration, which includes all R-39R subclasses, and there is a restricted R-39R class for evaporative cooling and ventilators. On a dual license, CR-39 or CR-58 Comfort Heating, Ventilating, Evaporative Cooling covers it (A.A.C. R4-9-103, R4-9-104).